Abstract
Thermomechanical performance of the first wall (FW) W/EUROFER sandwich type module is analyzed under DEMO reactor conditions. Engineering heat loads to the FW panels are estimated for steady state operation with the edge localized modes (ELMs). Calculations carried out by MEMOS code show the inhomogeneity of the material temperature due to discrete location of the water cooling tubes embedded into EUROFER. The hot spots are formed in the W armor and EUROFER between the cooling sectors and depend on the distance of their mutual locations. The bending stress due to vertical temperature gradients in W and EUROFER layers is calculated and remains smaller than the ultimate tensile stress for expected temperatures. Calculations show that under the Type I ELMs expected in DEMO the W surface melts at the ELMs peak positions and solidifies between ELMs. There is no temperature difference found between hot and cool spots during ELMs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.