Abstract

The cooling system of the superconducting toroidal field coil for the Next European Torus fusion reactor was investigated as part of the preliminary design activity. This system is based on the two-in-hand double-pancake-winding technique. The main objective of this study, based on the NET double-null configuration, was the evaluation of the cooling characteristics during normal operation of the coil, under steady-state conditions, and the quench characteristics, assuming correct operation of the protection system. Results of the analysis have shown that the proposed cooling system is adequate and no critical condition occurs during a quench.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.