Abstract

Thermodynamic analysis and flow rate optimization for the long double-tube latent heat thermal energy storage systems (LHTESS) are performed. Computer modeling is carried out using created software and is based on a developed 3D non-steady non-linear coupled thermo-fluid mathematical model that combines the apparent heat capacity method and finite volume method for the sodium nitrate (NaNO3) phase change materials (PCM) and for the Syltherm800 heat transfer fluid (HTF). The mathematical model and numerical algorithm are verified through comparison with experimental data. It is found that the laminar flow of HTF ensures the uniform temperature in PCM and in HTF and this temperature is equal to the PCM melting temperature. It is proved that the PCM and HTF average temperatures along the LHTESS can be equalized using spatial and temporal velocity variations of the HTF. Mutual impact of the heat transfer and fluid mechanics parameters in the long double-tube LHTESS was studied by correlation between Nusselt numbers and Reynolds numbers. The optimal HTF flow rate parameters were analyzed based on the non-equilibrium thermodynamics method. It is discovered that the laminar regime 0 < Re < 2000 and the turbulent regime 12000<Re<15000 are the most optimal for long double-tube LHTESS of the described geometry.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call