Abstract

Motivated by an increased interest in heavy liquid metal (lead or lead alloy) cooled fast reactors (LFR) and accelerator-driven system (ADS), the present paper presents a study on resistance characteristics and heat transfer performance of liquid lead bismuth eutectic (LBE) flow through a straight-tube heat exchanger and a U-tube heat exchanger. The investigation is performed on the TALL test facility at KTH. The heat exchangers have counter-current flow arrangement, and are made from a pair of 1-m-long concentric ducts, with the LBE flowing in the inner tube of 10 mm I.D. and the secondary coolant flowing in the annulus. The inlet temperature of LBE into the heat exchangers is from 200 °C to 450 °C with temperature drops from 0 °C to 100 °C within the LBE flow range of Re = 10 4–10 5. Analysis of the experimental results obtained provides a basic understanding and quantification of the regimes of lead–bismuth flow and heat transfer through a straight tube and a U-shaped tube. The unique data base also serves as benchmark and improvement for system thermal-hydraulic codes (e.g. RELAP, TRAC/AAA) whose development and testing were dominantly driven by applications in water-cooled systems. Lessons and insights learnt from the study and recommendations for the heat exchanger selection are discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.