Abstract

The Space Infrared Telescope for Cosmology and Astrophysics (SPICA) is a pre-project of JAXA in collaboration with ESA to be launched around 2025. The SPICA mission is to be launched into a halo orbit around the second Lagrangian point in the Sun-Earth system, which allows us to use effective radiant cooling in combination with a mechanical cooling system in order to cool a 3m large IR telescope below 6K. The use of 4K / 1K-class Joule-Thomson coolers is proposed in order to cool the telescope and provide a 4K / 1K temperature region for Focal Plane Instruments (FPIs). This paper introduces details of the thermal design study for the SPICA payload module in the Risk-Mitigation-Phase (RMP), in which the activity is focused on mitigating the mission’s highest risks. As the result of the RMP activity, most of all the goals have been fully satisfied and the thermal design of the payload module has been dramatically improved.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.