Abstract

Failure of steam-side oxide scales in high temperature components of boilers such as superheater and reheater tubes has significant effect on the safety of thermal power plants. Finite element analysis is carried out to investigate the failure issues of steam-side oxide scales in boiler tubes during thermal shock processes. The effects of different steam temperature variation durations on oxide scale failure issues have been analyzed. According to the results, appropriately lengthening variation duration can contribute to relieving oxide scale failure issues, and are subsequently proposed.