Abstract

The thermal load caused by the absorption of synchrotron radiation in X-ray optical elements of the Belok and RSA stations leads to optics elements heating and induces strains upon simultaneous cooling. The heating of the cooled first crystal in the double-crystal monochromator causes its bending and increases the reflected beam divergence, which, in turn, results in the monochromatic beam intensity loss [1]. Numerical simulation makes it possible to more accurately determine the strains, choose the optimal monochromator design, estimate the vertical sizes of the focal spot and wavelength resolution in the focusing channel, correctly design the system for cooling the mirror at the channel input, and choose a design providing the minimum temperature of the beam-limiting slit knives.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.