Abstract
The problem of energy saving is relevant nowadays. Great attention is especially paid to improving the energy efficiency of different building envelopes, since the heat consumption is a significant part of total costs for utility needs. Purpose: The aim of the paper is to study the state of the building envelopes nearby the outer corner. Research findings: Methods of reduction of the negative impact of the thermal bypass nearby the corner manifest themselves in condensation, mold, and subsequently lead to the envelope destruction. The use of insulated bevel edge leads to better results than that without insulation. But the minimum dew point temperature remains at corners and does not exceed 13.5 °C. Only in this case, the minimum dew point temperature moves to bevel edges. Value: The thermal bypass (outer corner) effect on the temperature field of its inner surface is studied. Three wall thicknesses are investigated: 510, 640, and 770 mm. It is shown that in all cases the corner temperature decreases below the dew point temperature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Vestnik Tomskogo gosudarstvennogo arkhitekturno-stroitel'nogo universiteta. JOURNAL of Construction and Architecture
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.