Abstract

Controlled-release fertilizers (CRF) use a controlled-release technology to enhance the nutrient use efficiency of crops. Many factors affect the release of nutrients from the waterborne polymer-coated CRF, but the effects of thermal post-treatments remain unclear. In this study, a waterborne polyacrylate-coated CRF was post-treated at different temperatures (30 °C, 60 °C, and 80 °C) and durations (2, 4, 8, 12, and 24 h) after being developed in the Wurster fluidized bed. To characterize the polyacrylate membrane, and hence to analyze the mechanism of nutrient release, Fourier transform mid-infrared spectroscopy, scanning electron microscopy, and atomic force microscopy were employed. The nutrient-release model of CRF post-treated at 30 °C was the inverse “L” curve, but an increased duration of the post-treatment had no effect. The nutrient-release model was “S” curve and nutrient-release period was enhanced at higher post-treatment temperatures, and increased post-treatment duration lengthened slowed nutrient release due to a more compact membrane and a smoother membrane surface as well as a promoted crosslinking action. CRF equipped with specified nutrient-release behaviors can be achieved by optimizing the thermal post-treatment parameters, which can contribute to the development and application of waterborne polymer-coated CRF and controlled-release technologies.

Highlights

  • More commercially successful due to their improved controlled-release rate, release time, and release pattern[17,18]

  • There are more than 20 operational parameters involved in the Wurster fluidized bed coating process[21], and some of the key parameters in the spray coating process have been analyzed and found to significantly affect coating morphology and quality, which in turn affect the behavior of the CRF12,22

  • Nutrient release from the CRF was detected in distilled water, and the membrane changes were observed using Fourier transform mid-infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), and electron digital caliper and atomic force microscopy (AFM)

Read more

Summary

Introduction

More commercially successful due to their improved controlled-release rate, release time, and release pattern[17,18]. The objective was to examine the effects of thermal post-treated parameters on the nutrient-release behavior of a waterborne polyacrylate-coated CRF.

Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call