This experimental study examines the properties of heat transfer, pressure drop and thermal performance factor (TPF) of a narrow undulant channel enhanced by skew sinusoidal wall-waves and 45° ribs. Detailed Nusselt number (Nu) distributions over the wavy ribbed channel wall are generated by the steady-state infrared thermography method and examined along with the accompanying pressure drop coefficient (f) in the test Reynolds number (Re) range of 800–9000. With references to the Nusselt numbers (Nu∞) and pressure drop coefficients (f∞) of smooth plain tube, the area-averaged heat transfer enhancement (HTE) ratios, pressure drop augmentations (f/f∞) and TPF for the tested undulant channel are compared with those obtained from other passive HTE devices. Empirical correlations evaluating the area-averaged Nusselt number (Nu¯) over the undulant ribbed channel wall and the pressure drop coefficients are generated to assist design activities using this newly devised HTE measure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.