Abstract

The air flow rate available for cooling of notebook computers is very limited. Thus, notebook computer manufacturers desire a “passive” cooling method. Heat pipes are typically used to transport the heat from the CPU to a forced convection, air-cooled condenser. This paper describes a passive, keyboard sized aluminum Integrated Plate Heat Pipe (IP-HP) that has been developed for notebook computers. Analysis was performed to estimate the several thermal resistances in the heat pipe, including the effect of the vapor pressure drop. The modified design using a heat spreader at the evaporator significantly reduces the heat pipe resistance. Further work was done to evaluate the thermal contact resistance at the IP-HP/CPU interface. Test results show that the IP-HP can reject 18 W while maintaining the CPU 65°C above ambient temperature.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.