Abstract

A sealed space between absorber and cover glass in a flat plate solar collector makes it possible to reduce the influence of humidity condensate and dust at the same time as the enclosed space can be filled with a suitable gas for lowering the heat losses. This article describes the influence of different gases on the heat losses in a typical flat plate solar collector. A model of a gas-filled flat plate solar collector was built in Matlab with standard heat transfer formulas. The results show that the overall heat loss can be reduced by up to 20% when changing from air to an inert gas. It is further possible to reduce the distance between absorber and cover in order to reduce the mechanical stresses in the material with similar heat losses.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.