Abstract

ABSTRACT Thermal characteristics of water in a ground U-tube with twisted tape inserts were addressed. At inlet temperatures of 60°C to 75°C, and Reynolds numbers of 3000 to 9000, the surface heat transfer coefficients for water with twisted tapes ranged from 442 to 897 W m−2 K−1, which were higher than that in smooth tube, 384–810 W m−2 K−1. Average convective heat transfer coefficient for the smooth tube in sand/graphite blend ameliorated by 36% compared to that in sand. Average apparent thermal diffusivities of sand/graphite at hot end temperature of 70°C rose by about 17% compared to sand.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.