Abstract

Thiswork presents an experimental study on enhanced heat transfer and pressure loss characteristics in a tube having a uniform heat-fluxed wall by using small double and triple co-and counter-twisted tapes at two twist ratios, y/w=4 and 4.5. The investigation has been conducted for Reynolds number from 5300-20,000. The experimental results of the heat transfer and pressure drop are proposed in terms of Nusselt number and friction factor, respectively.The experimental results reveal thatthe maximum TEF for the triple counter-twisted tapesat smaller twist ratio isabout 1.26.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.