Abstract
Semi-transparent PV glazing are promising in Building Integrated Photovoltaic (BIPV) applications. They provide daylight control, energy saving and power generation. The selection of optimal Photovoltaic (PV) glazing requires the accounting for various factors such as location, orientation and glazing transparency. In this work, thermal performance of Cadmium telluride (CdTe) based semi-transparent PV glazing of different transparencies was evaluated in UK for South and South-West orientations. Thermal performance was analysed in terms of U-value, SHGC and cooling load. Results revealed that least transparency CdTe PV glazing can have U-values as low as 1.52 W/m2K. The use of least transparency PV glazing can reduce 96% of solar heat gains and 23.2% of cooling energy compared to conventional clear glazing when used in South-West orientation. The selection of optimum glazing was discussed taking into consideration occupants’ optical comfort and health.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.