Abstract

The thermal performance of one-ended evacuated tubes solar air collector is experimentally investigated during the winter season at NIT Kurukshetra, India [29 ° 58′(latitude) North and 76 ° 53 ′ (longitude) East]. The collector consists of 15 one-ended evacuated tubes with different lengths of directional inner aluminium tubes (inserted tubes) and a manifold channel, with air used as a working fluid. The inlet air flows through the directional inner aluminium tubes as a result of forced convection. In this experiment, evacuated tubes are used for producing hot air corresponding to different lengths of directional aluminium tubes without using any intermediate fluid. The temperature of the outlet air depends on the air flow rate, length of the directional aluminium tube and solar intensity. The maximum temperature difference between outlet air and inlet air at solar intensity 904 W/m2 was found to be 72.7 °C with a flow rate of 5.06 kg/h and length of 0.83 m.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.