Abstract
Soft error rate (SER) testing and measurements of semiconductor circuits with different operating voltages and operating conditions have been performed using the thermal neutron beam at the Radiation Science and Engineering Center (RSEC) at Penn State University. The high neutron flux allows for accelerated testing for SER by increasing reaction rate densities inside the tested device that gives more precision in the experimental data with lower experimental run time. The effect of different operating voltages and operating conditions on INTEL PXA270 processor has been experimentally determined. Experimental results showed that the main failure mechanism was the segmentation faults in the system. Failure response of the system to the operating conditions was in agreement with the general behavior of SERs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.