Measurements and simulations of thermal neutron attenuation by printed circuit boards (PCBs) are compared. Attenuation coefficients in typical epoxy-resin/glass-fiber substrate material can be as high as 2 cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> , corresponding to 27% attenuation by 1.6 mm of the substrate. Attenuation is attributed to neutron scattering off hydrogen in the resin acting in synergy with absorption by boron in the glass; this effect is substantially greater than that estimated from absorption by boron alone. Design of thermal neutron detector assemblies should take this attenuation into account and may require board thickness to be minimized or specialized substrate materials to be used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.