Abstract

Partial tears of the anterior cruciate ligament (ACL) are common, representing 10% to 28% of all ACL tears. Untreated partial tears of the ACL may go on to complete rupture in up to 42% of cases, and as few as 30% of patients return to their preinjury activity level. The purpose of this study was to evaluate the effectiveness of thermal modification for the treatment of partial tears of the ACL. A prospective, nonrandomized consecutive case series. Thirteen patients with a partial tear of a native ACL were treated with thermal modification of the ACL. All patients had a preoperative office examination significant for an end-point to Lachman examination and pivot-glide. All patients had bilateral preoperative KT-1000 measurements. All tears were confirmed by arthroscopy to constitute a 50% or less loss of structural integrity of the ligament. The ACL underwent thermal modification using the Oratec thermal probe (Oratec Interventions, Menlo Park, CA), and was examined by intraoperative KT-1000 testing. Patients were evaluated postoperatively at 6 weeks, and at 3, 6, 12, and 24 months by office examination and functional outcome scoring. KT-1000 arthrometer testing revealed a mean side-to-side difference of 4.35 mm preoperatively (SD = 1.1 mm). At the most recent follow-up, averaging 23 months (range, 18 to 28 months), 10 patients had a negative Lachman examination and no pivot-shift. Two patients had persistent grade II Lachman and complaints of giving way 3 months postoperative. Both patients underwent ACL reconstruction. One patient was lost to follow-up. Of the remaining 10 patients, all patients achieved full extension, and the average flexion range of motion was 131 degrees (SD = 5.6). Compared with the preoperative KT-1000 arthrometer testing, the most recent evaluation revealed a decrease in mean side-to-side difference to 1.9 mm (SD = 1.5 mm). At most recent follow-up, the mean Lysholm score was 96.3 (SD = 4.4), the mean Tegner score was 6.1 (SD = 1.2), and the mean Cincinnati score was 94 (SD = 3.0). With cautious application, thermal modification may be a viable treatment option for partial tears of the ACL in a select subset of patients. Further investigation is necessary to determine the long-term effectiveness of this procedure. Level IV, Therapeutic Case Series Study (no or historical control group).

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call