Abstract

A system-level model for a combatant ship's chilled water system is described and developed in this paper. Some major thermal components related to dynamic aspects are identified in detail. Given the vital heat load for each compartment and equipment, the steady state performances are evaluated for the normal two-loop alignment. Dynamic behaviors are also investigated at different operating conditions. Several extreme cases such as pipe rupture in the vital branch and time to overheat are also studied to evaluate the system survivability. The work presented in this paper continuous the efforts for using Virtual Test Bed as a potential system-level dynamic simulation platform for an all-electric ship thermal management.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.