Abstract

For through-silicon optical probing of microprocessors, the heat generated by devices with power over 100W must be dissipated 1. To accommodate optical probing, a seemingly elaborate cooling system that controls the microprocessor temperature from 60 to 100°C for device power up to 150 W was designed 2. The system parameters to achieve the desired thermal debug environment were cooling air temperature and air flow. A mathematical model was developed to determine both device temperature and input power. The 3D heat equation that governs the temperature distribution was simplified to a case of a 1D rod with one end at the device center and the other at the cooling air intake. Thus the cooling system was reduced to an analytical expression. From experimental data, we computed all coefficients in the model, then ran extensive tests to verify—the accuracy was better than 10% over the entire temperature and power ranges.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.