Abstract
A spray cooling system was developed and tested for thermal management of power inverter modules utilized in automotive applications. The system featured an array of 1×2 pressure atomized nozzles that used 88°C boiling point antifreeze coolant with 0.15-l/min.cm2 liquid flow rate and 145-kPa pressure drop. A 2-cm2 simulated device, having two kinds of enhanced spray surface with microscale structures, reached up to 400-W/cm2 heat flux with as low as 14 °C surface superheat. These experimental results demonstrated the capability of greatly reducing the overall thermal resistance of the inverter modules that are commonly cooled with single-phase convective systems. The long-term reliability of the spray cooling was assessed with 2000 h of testing time. Performance of the presented system proved the spray cooling of power electronics as an attractive option that enables high power densities while maintaining acceptable and uniform device temperatures. In addition, due to the use of high temperature coolant at low flow rates, the spray cooling offers a compact and efficient system design.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Components, Packaging and Manufacturing Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.