Abstract

A parametric analysis of natural convection in air, in a channel–chimney system, symmetrically heated at uniform heat flux, obtained by means of a numerical simulation, is carried out. The analyzed regime is two-dimensional, laminar and steady-state. Results are presented in terms of wall temperature profiles in order to show the more thermally convenient configurations which correspond to the channel–chimney system with the lowest maximum wall temperature. For the considered Rayleigh number, the difference between the highest and the lowest maximum wall temperatures increases with increasing the channel aspect ratio. The optimal expansion ratio values depend strongly on the Rayleigh number and extension ratio values and slightly on the channel aspect ratio. Correlations for dimensionless mass flow rate, maximum wall temperature and average Nusselt number, in terms of Rayleigh number and dimensionless geometric parameters are presented in the ranges: 5 ⩽ Ra ∗ ⩽ 2.0 × 10 4 , 1.5 ⩽ L / L h ⩽ 4.0 and 1.0 ⩽ B / b ⩽ 4.0 .

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.