Abstract

ABSTRACTA numerical three-dimensional flow and conjugate heat transfer in circular minichannel-based multi-row heat sink is presented in this article. Effects of geometrical parameters including channel dimensions, channel arrangements (inline or staggered), and the number of channel rows with a single-pass flow on the thermal performance of the heat sink are presented. The determination of the bottom surface temperature, average heat transfer coefficient, thermal resistance as well as the pressure drop was reported. The number of rows and the diameter of the circular channel for a constant Reynolds number were found to have a remarkable cooling effect on the heat sink. It was found out that in the case of using four channel rows with the channel diameter of 1 mm, the cooling capacity is 88.5 W/cm2 compared to 28 W/cm2 for a single row 1 mm diameter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.