Abstract
The HTR-10 is the first high temperature gas-cooled test module reactor built in China. In the accident analysis, typical design basis accident and beyond design basis accident (BDBA), including the reactivity accident, the loss of external power ATWS, the air ingress accident and water ingress accident into the primary system are selected and detailed analyzed. The results show that the HTR-10 has inherent safety properties. The maximum fuel element temperature will not exceed the limit value 1230 °C. The total amount of graphite corrosion maintains no more than 320 kg, the exposure ratio of first coated particles is less than 2.4% in the BDBA. The released radioactivity is limited at a low level and the ability of fuel particles to retain fission products is not corrupted. Even the consequence of the severest hypothetical accident has no safety danger to the reactor. The reactor can shut itself down via its negative temperature coefficient of reactivity in heat-up conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.