• A mathematical model has been developed to investigate the thermal-hydraulic performance of ITER tungsten divertor monoblock. • The model predicts the thermal response of the divertor structural materials and coolant tube. • The model accounts for the melting, vaporization, and solidification of the upper layer of the divertor facing plasma. • The model is verified against a previous calculation in the literature for DEMO divertor at an incident surface heat flux of 10 MW/m 2 . • The model is used to simulate the divertor materials response subjected to a VDE. The divertor is a fundamental component of fusion power plants, being primarily responsible for power exhaust and impurity removal via guided plasma exhaust. Due to its position and functions, the divertor has to sustain very high heat flux arising from the plasma (up to 20 MW/m 2 ), while experiencing an intense nuclear deposited power, which could jeopardize its structure and limit its lifetime. Therefore, attention has to be paid to the thermal–hydraulic design of its cooling system. In this work a mathematical model has been developed to investigate the steady state and transient thermal–hydraulic performance of ITER tungsten divertor monoblock. The model predicts the thermal response of the divertor structural materials and coolant tube. The coolant tube is divided into specified axial regions and the divertor plate is divided into specified radial zones, and then a two-dimensional heat conduction calculation is performed to predict the temperature distribution for both steady and transient states. A two-dimensional numerical finite difference technique is adapted in Cartesian coordinate system where the implicit scheme is used for transient calculation. The model also accounts for the melting, vaporization, and re-solidification of the upper layer of the divertor facing plasma. The selected heat transfer correlations cover all possible operating conditions of ITER under both normal and off-normal situations. The model is verified against a previous calculation in the literature for DEMO divertor at an incident surface heat flux of 10 MW/m 2 . The model is then used to predict the steady state thermal behaviour of the divertor under incident surface heat fluxes ranges from 2 to 20 MW/m 2 for a bare cooling tube and cooling tube with swirl-tape insertion. It calculates the maximum tube surface heat flux and the minimum critical heat flux ratio for all cases as well. The model is also used to simulate the divertor materials response subjected to high heat flux during a vertical displacement event (VDE) where 60 MJ/m 2 plasma energy is deposited over 500 ms.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.