Abstract

Abstract The thermal hydraulic characteristics of a double-walled tube steam generator designed for sodium-cooled nuclear reactors are presented. The double-walled tube construction, along with double-barrier welds for tube-to-tubesheet joints, virtually eliminates the probability of heat transfer tube failure. Considerations are given to the use of the internal core tube, helical vane swirl generator, external protector tube, and variably perforated flow baffles to improve thermal and hydraulic performance of the steam generator. These thermal hydraulic design features with a particular reference to a 432 MW PRISM steam generator are discussed.