Abstract

Removing the residual heat from a nuclear reactor is an important safety aspect of thermal hydraulic analysis. In this study, a typical VVER-1000 reactor residual heat removal system has been evaluated using RELAP5 thermal hydraulic loop code during cool-down. Reactor cooling down starts from hot state temperature and then continues to the cool-down stages with 130°C and 70°C, respectively. The second stage of cooling down is the boundary of the reactor repair condition. Main cooling pump head, steam generator (SG) water level, system pressure, the level of coolant in the pressurizer (PRZ), and the temperature of fuel element are examined in a steady state condition. PRZ level, primary circuit and secondary circuit pressure/temperature, and SG water level are evaluated during 32,000s after cool-down scenario. By comparison, it concluded that the results of RELAP5 code are in agreement with plant experimental data and final safety analysis report (FSAR). Thus, it is proved that the studied reactor is capable to remove the residual heat generated during shutdown. Moreover, RELAP5 is properly recommended for analysis of the VVER-1000 pressurized water reactor during cool-down.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.