Abstract

In cryo-sorption cryopump developed at Institute for Plasma Research (IPR), hydro formed cryopanels are cooled down to 4.5K to adsorb hydrogen isotopes and helium gas. These panels are coated with activated carbon. To maintain continuous high pumping speed, panels require frequent regeneration to remove adsorbed gases. Regeneration comprises of two modes of operation, cool down from 300K to 4.5K and warm up from 4.5K to 100–300K. Thermal hydraulic characteristics were studied involving two phase flow of helium through a hydro formed cryopanel of size 500mm (l) ×100mm (w) with a sheet thickness of 1.5mm. Cool down time and transient parameters of two phase helium flow rate were estimated at real time operating conditions. The results are assessed and show good agreement with experiments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.