Abstract
Cracks have been observed in the welds of the shroud support access hole cover plates at Peach Bottom Unit 3 as well as at the Chinshan nuclear power plant. The cracks could potentially result in complete weld failure and, as a consequence, a coreflow bypass. Analysis of the postulated complete weld failure of the Chinshan nuclear power plant shroud support access hole cover plate is performed with RETRAN-02/MOD3. The results show that some confusing phenomena could be observed. The reactor operator should be aware of the phenomena to avoid the likelihood of misoperation. Also, a special procedure needs to be established to deal with this event.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.