Abstract
In order to obtain a better understanding of the thermal hazard of hydrazine and nitric acid mixtures which are used in plutonium and uranium recovery by extraction (PUREX) process during recycling of spent fuel in nuclear plant, DSC was carried out for the mixed system made by the small scale reaction calorimeter super-CRC in various conditions. It was found that the concentration of the nitric acid has a strong influence on the thermal behavior of the mixed system, and hydrazine nitrate which is formed in the reaction in the mixture was determined by DSC with FTIR analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.