Abstract

The validation of a numerical study for the coupled analysis of thermal protection systems and hot structures in interaction with a high-enthalpy hypersonic flowfield was carried out. The simulation of the thermal fluid-structure interaction on a ceramic flat-plate model was conducted by means of the DLR TAU code and of the commercial software ANSYS. The comparison with experimental results was achieved with tests in the high-enthalpy wind tunnel facility L3K in Cologne. The computations were shown to properly capture the temperature trend on the considered surface, but the temperature values were underpredicted. Further numerical investigations pointed out a partially catalytic behaviour of the ceramics at such temperature levels and a non-perfect thermal contact between structure parts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.