Abstract
Lithium-ion (Li-ion) battery faults are potentially hazardous to battery health, safety and performance. Thermal fault mechanisms represent a critical subset of such failures. To ensure safety and reliability, battery management systems must have the capability of diagnosing these thermal failures. We present a Partial Differential Equation (PDE) model-based scheme for diagnosing thermal faults in Li-ion batteries. For this study, we adopt a distributed parameter one-dimensional thermal model for cylindrical battery cells. The diagnostic scheme objective is to detect and estimate the size of the thermal fault. The scheme consists of two PDE observers arranged in cascade. The first observer, denoted as Robust Observer, estimates the distributed temperature inside the cell under nominal (healthy) and faulty conditions. The second observer, denoted as Diagnostic Observer, receives this estimated temperature distribution, and in turn outputs a residual signal that provides the fault information. Lyapunov stability theory has been utilized to verify the analytical convergence of the observers under heathy and faulty conditions. Simulation studies are presented to illustrate the effectiveness of the scheme.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.