Abstract

1. A method has been developed that permits comparative thermal-fatigue tests at cryogenic temperatures. 2. Thermal cycling under load has a substantial effect on the strength of metals, lowering the strength 18–22% in 104 cycles. 3. Ductile Cr−Ni austenitic steel 12Kh18N10T is the least sensitive to thermal cycling.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.