Abstract
Despite success in cryopreservation of cells in suspension, cryopreservation of cells in monolayers is still challenging. One of the major problems is detachment of the cells from the substrate which occurs during cryopreservation. We hypothesized that this detachment may be due to a mismatch in the coefficient of linear thermal expansion αL between glass and the frozen cell layer which manifests as residual stress and stress relaxation. This mismatch results in a difference between the thermal expansion of ice and glass as they undergo temperature changes. Rinzl plastic coverslips were selected as a possible substitute for glass because Rinzl has an αL (60 × 10−6/K) similar to that of ice (51 × 10−6/K) whereas glass has a much lower αL (5 × 10−6/K). V79-4 Chinese hamster fibroblasts were cultured on both glass and Rinzl coverslips until confluent and the area of coverage was measured before and after freezing at −9 °C. The glass coverslips showed significant loss of cells (coverage = 77.9 ± 8.0%) compared with Rinzl (coverage = 97.9 ± 1.4%). We concluded that Rinzl coverslips may improve cell attachment in future monolayer cryopreservation experiments.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.