Abstract

The optimal design model, based on exergy analysis, of an irreversible cogeneration cycle has been presented using finite-time thermodynamics. The external irreversibility is due to the thermal resistance between the system and the heat reservoirs while the internal irreversibility is due to the non-isentropic compression and expansion process within the system. The internal irreversibility of the irreversible cogeneration cycle is characterised by a single parameter representing the ratio of relevant entropy differences. The presence of this irreversibility parameter shows that a cogeneration power plant with internal irreversibilities delivers less exergy output and has a lower efficiency than those of the reversible and endoreversible cycles. The model presented here is of more use when compared to those obtained by earlier researchers.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call