Abstract

The final goal of this study is to implement and to test a thermal energy storage (TES) system using different phase change materials (PCM) for solar cooling and refrigeration applications. A high temperature pilot plant able to test different types of TES systems and materials was designed and built at the University of Lleida (Spain). This pilot plant is composed mainly by three parts: heating system, cooling system, and different storage tanks. The pilot plant uses synthetic thermal oil as heat transfer fluid (HTF) and has a working temperature range from 100°C to 400°C. Two different PCM were selected after a deep study of the requirements of a real solar cooling plant and the available materials in the market, finally d-mannitol with phase change temperature of 167°C and hydroquinone which has a melting temperature of 172.2°C were used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.