Abstract
To determine the effect of covering infant incubators on incubator wall and air temperatures, as well as on infant temperatures. A within-subject ABA design, in which blankets covering the incubators were removed for a 30-minute period and then replaced. A neonatal intensive-care unit. Eight medically stable infants (gestational age, 28-33 weeks; birth weight, 913-1,947 g; and postnatal age, 2-39 days). Incubator wall and air temperatures as well as infant temperatures were measured during three study conditions: incubators covered (30 minutes), uncovered (60 minutes), and re-covered (30 minutes). Incubator air and wall temperature; infant temperature. All incubator walls decreased in temperature after being uncovered; the decrease ranged from 0.6-2.2 degrees C. Although infants maintained relatively stable body temperatures during the uncovered period, the energy cost to their thermoregulatory efforts is unknown.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of obstetric, gynecologic, and neonatal nursing : JOGNN
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.