Abstract
Thermal-diffusivity measurements using the laser-flash method have been investigated in order to establish a thermal diffusivity standard. In many cases, thermal-conductivity values of bulk materials are calculated from the thermal diffusivity, specific heat capacity, and bulk density. The thermal diffusivity is one of the transport properties. It depends on the material and is sensitive to the structure. So, it is important to measure the thermal diffusivity of each material. The laser-flash method is one of the most popular methods for thermal-diffusivity measurements of bulk materials above room temperature. Because the method realizes a short-time method and is a non-contact method, it is very suitable for practical use. And it is known as a highly reliable measurement since one-dimensional heat diffusion phenomena observed in these measurements are simple. On the other hand, more reliable values measured by the method are important in the view of thermal design. According to the background, there is a need of a standard for thermal-diffusivity measurements using the laser-flash method to obtain reliable thermal diffusivities. The National Metrology Institute of Japan (NMIJ) in AIST has established reference materials for the laser-flash method and is supplying them. However, they are not sufficient to cover the whole range of thermal-diffusivity measurements. Thus, some candidate materials have been investigated to establish another reference material. Carbon materials are considered since it is preferable for the laser-flash method that the material is optically nontransparent and dark colored (ideally black). In this study, the thermal diffusivity of a pyrolytic graphite that is expected to be a candidate reference material for the laser-flash method is investigated. It was found that the intrinsic thermal diffusivities can be determined along the in-plane and cross-plane directions. The high thermal diffusivity of the in-plane direction, \(1.19 \times 10^{-3}\,\mathrm{m}^{2}\,{\cdot }\,\mathrm{s}^{-1}\), was successfully observed at room temperature. The thermal diffusivity along the cross-plane direction was determined to be \(4.8 \times 10^{-6}\,\mathrm{m}^{2}\,{\cdot }\, \mathrm{s}^{-1}\). It has indicated that the pyrolytic graphite has a large anisotropy from the view of the thermal diffusivity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.