Abstract
This paper concerns the thermal design of Earth-to-Air Heat Exchanger (EAHE). The paper presents new transient semi-analytical models to estimate i) the disturbed soil thermal resistance of EAHE pipe as a function of duration of operation and ii) thermal performance of EAHE operating under transient conditions. The main aim of this study is to evaluate the parameter choices of this new model for short period of continuous operation of the system (less than 70 h). The results show that time discretization steps of 15 min and 1 h present and lead to appreciable results compared to the experiments. Therefore, the variation of the layer length step of the buried pipe does not alter simulation results. In terms of precision of the soil temperature profile, refined solutions were obtained by the decreasing of the disturbed soil radius and the increasing the number of roots of Bessel's functions. Furthermore, the effect of the variation of surrounding soil radius is discussed for short period of continuous operation of the system. The time step of 1 h and the interval of the surrounding soil radius of 0.4 m–1.1 m are found accurate for good results with a reasonable computational time.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.