Abstract
The thermal design of detector in a solar X-ray and extreme ultraviolet imager is performed according to the specific requirements for the temperature of its optical system. First, the detector structure and the thermal control index are introduced. Second, the external heat fluxes of the imager is analyzed, and the position of the heat dissipation surface is confirmed. Then, the factors that influence the temperature of the charge-coupled device are analyzed. Large-thermal-resistance insulating technology is adopted, and a detailed thermal design scheme is proposed based on the difficulty of the thermal design. A thermal analysis model is constructed using thermal model generator software. Finally, a thermal balance test is performed in a vacuum environment. Simulation results show that the temperature of the charge-coupled device ranges from to , which meets the thermal control index requirements. Test results indicate that the charge-coupled device temperature range from to , which also satisfies the design requirements. Additionally, the test values are in good agreement with the calculated results, which verify that the thermal design is appropriate.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.