Abstract

An isothermal method was applied to measure the thermal decomposition of reactive solids in a sensitive heat flux reaction calorimeter, C80. This technique experimentally clarified the decomposition mechanisms of unstable substances based on the shapes of the heat flow curves, from which autocatalysis, first-order reaction or pseudo-autocatalytic reaction could be recognized. Kinetic parameters were derived from the measured data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.