Abstract

Abstract This paper presents the results of laboratory tests which simulated the effect of repeated cycles of heating and cooling of a spot on a catalytic-cracker regenerator shell. A specimen was made to resemble in all feasible respects a 6-ft-square piece of a cylindrical shell of a regenerator, including welded seams and vapor stops. After 50 cycles of heating to 900 F at the center of the spot for 1 or 2 days, then cooling to near room temperature, the plate was radiographed, its microstructure examined, and its mechanical properties determined. No evidence of cracking or of deterioration of the metallic structure was observed. Some distortion was produced by the first few cycles of heating but continued cycling did not produce further distortion.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.