Abstract

Low-pressure thermal conductivity and thermal diffusivity measurements are reported for argon and nitrogen in the temperature range from 295 to 350 K at pressures from 0.34 to 6.9 MPa using an absolute transient hot-wire instrument. Thermal conductivity measurements were also made with the same instrument in its steady-state mode of operation. The measurements are estimated to have an uncertainty of 1% for the transient thermal conductivity, 3% for the steady-state thermal conductivity, and 4% for thermal diffusivity. The values of isobaric specific heat, derived from the measured thermal conductivity and thermal diffusivity, are considered accurate to 5% although this is dependent upon the uncertainty of the equation of state utilized.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call