Abstract

Ground-based thermal infrared surveys can contribute to complete heat budget inventories for fumarole fields. However, variations in atmospheric conditions, plume condensation and mixed-pixel effects can complicate vent area and temperature measurements. Analysis of vent temperature frequency distributions can be used, however, to characterise and quantify thermal regions within a field. We examine this using four thermal infrared thermometer and thermal image surveys of the Vulcano Fossa fumarole field (Italy) during June 2004 and July 2005. These surveys show that regions occupied by low temperature vents are characterised by distributions that are tightly clustered around the mean (i.e., the standard deviation is low), highly peaked (positive kurtosis) and skewed in the low temperature direction (negative skewness). This population is associated with wet fumaroles, where boiling controls maximum temperature to cause a narrow distribution with a mode at 90–100°C. In contrast, high temperature vent regions have distributions that are widely spread about the mean (i.e., the standard deviation is high), relatively flat (negative kurtosis) and skewed in the high temperature direction (positive skewness). In this dry case, fumaroles are water-free so that maximum temperatures are not fixed by boiling. As a result greater temperature variation is possible. We use these results to define two vent types at Vulcano on the basis of their thermal characteristics: (1) concentrated (localized) regions of high temperature vents, and (2) dispersed low temperature vents. These occur within a much larger region of diffuse heat emission across which surfaces are heated by steam condensation, the heat from which causes elevated surface temperatures. For Vulcano's lower fumarole zone, high and low temperature vents occupied total areas of 3 and 6 m2, respectively, and occurred within a larger (430 m2) vent-free zone of diffuse heat emission. For this lower zone, we estimate that 21–43 × 103 W of heat was lost by diffuse heat emission. A further 4.5 × 103 W was lost by radiation from high temperature vents, and 6.5 × 103 W from low temperature vents. Thus, radiative heat losses from high and low temperature vents within Vulcano's lower fumarole zone respectively account for 10% and 15% of the total heat lost from this zone. This shows that radiation from open vents can account for a non-trivial portion of the total fumarole field heat budget.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.