Abstract

The high spatial, temporal, and thermal resolution of the thermal imaging system Optotherm EL InfraSight 320 is used for investigation of the thermal behavior of the ionic electroactive polymer (IEAP) actuators. The resolution of 10-20 pixels in the direction of their thickness is close to the theoretical limit restrained by the infrared light wavelength registered by the imaging system. The videos, recorded with the frame rate of 30 fps, demonstrate showy the propagation of heat along the membrane. The analysis of the thermal images provides the foundation for precise modeling of the IEAP actuators, taking into account the thermally induced mechanical and electrochemical effects. Experiments conducted with the IEAP actuators of different types (ionic polymer-metal composite, carbon-polymer composite, conducting polymer actuators) allow comparing their efficiencies. The experiments show demonstrable, that the IEAPs, used improperly, overheat to the inadmissible temperatures within seconds only. This, in turn, evaporizes the volatile electrolyte, and shortens the life expectancy of the IEAP devices.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.