Abstract

Results of investigation are presented for an experimental convective-heat-transfer unit and the aerodynamic resistance of tube banks formed from three types of bimetallic finned tubes (BFT). It is demonstrated that the most important indicators of the thermotechnical efficiency of BFT are the thermal contact resistance (TCR) and its variation with increasing temperature. We were the first to determine the TCR during a rise and fall in the temperature of a steel bearing tube.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.