Abstract

The phase transition law of Fe-N system is very important for efficiently synthesizing single-phase <i>γ</i>'-Fe<sub>4</sub>N thin films. The <i>γ</i>"-FeN thin films are deposited on silicon wafers via DC reactive magnetron sputtering; some of them are stripped from the silicon wafers and measured by using the synchronous thermal analysis (TG-DSC) for studying the phase transition law of Fe-N system. The results of TG-DSC show that at a heating rate of 10 ℃/min, the Fe-N system has five phase transitions in a temperature range between room temperature (RT) and 800 ℃, i.e. I (330−415 ℃): <i>γ</i>''-FeN→ξ-Fe<sub>2</sub>N with an endothermic value of 133.8 J/g; II (415−490 ℃): ξ-Fe<sub>2</sub>N→ε-Fe<sub>3</sub>N with no obvious latent heat of phase change; III (510−562 ℃): ε-Fe<sub>3</sub>N→<i>γ</i>'-Fe<sub>4</sub>N with an exotherm value of 29.3 J/g; IV (590−636 ℃): <i>γ</i>'-Fe<sub>4</sub>N→<i>γ</i>-Fe with an exotherm value of 42.6 J/g; V (636−690 ℃): <i>γ</i>-Fe→α-Fe with an endothermic value of 14.4 J/g. According to the phase transition law of Fe-N system, the crystal phase of iron nitride thin film is effectively regulated by vacuum annealing. The x-ray diffraction pattern (XRD) results show that the iron nitride thin film obtained by direct-sputtering in pure N<sub>2</sub> is a single-phase <i>γ</i>"-FeN film, and it becomes a single-phase ξ-Fe<sub>2</sub>N film after being annealed at 350 ℃ for 2 h, a single-phase ε-Fe<sub>3</sub>N film after being annealed at 380 ℃ for 2 h, and a single-phase <i>γ</i>'-Fe<sub>4</sub>N film after being annealed at 430 ℃ for 7 h. The annealing temperature for the phase transition of Fe-N thin film is generally lower than that predicted by the TG-DSC experimental results, because it is affected by the annealing time too, that is, prolonging the annealing time at a lower temperature is also effective for regulating the crystal phase of Fe-N thin film. The magnetic properties of the Fe-N thin film are also studied via vibrating sample magnetometer (VSM) at room temperature. The <i>γ</i>'-Fe<sub>4</sub>N polycrystalline thin film shows an easy-magnetized hysteresis loop for the isotropic in-plane one, but a hard-magnetized hysteresis loop with a large demagnetizing field for the out-of-plane one, which belongs to the typical magnetic shape anisotropy. However, their saturation magnetizations are really the same (about 950 emu/cm<sup>3</sup>) both in the plane and out of the plane.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.