Abstract
EHA has the characteristics of high-power density, which brings serious heat generation and heat dissipation challenges. High speed and high-pressure piston pump is one of the main heating elements of EHA. Its leakage fluid provides cooling medium for EHA motor to ensure the normal operation of the system. Temperature has an important impact on the life and performance of piston pump and EHA. Therefore, it is very significant to accurately predict the oil temperature rise for the structure and heat dissipation design of piston pump and EHA. In this paper, the heat transfer and generation characteristics of EHA piston pump are analyzed in detail. A simulation model is built by AMESim platform, which can be used to predict the outlet and leakage oil temperature under a fixed inlet temperature. The simulation and test results are in good agreement under some working condition.KeywordsAxial piston pumpThermal modelHeat transfer model
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.