Abstract
Excellent vacuum performance ensures a high beam transmission efficiency of the neutral beam injector (NBI). The vacuum performance is mainly determined by the cryoperformance of the cryopanel of the cryocondensation pumps which are the main vacuum pumps of NBI. In order to optimize the cryoperformance, the requirements for the temperature distribution and the heat load of the cryopanel are analysed and the factors that affect the cryopanel's temperature distribution are studied. The results indicate that the temperature difference of the cryopanel can be reduced by fabricating the cryopanel with high thermal conductivity material, increasing its thickness and cutting the distance between the two upward cooling pipes. The results may be applied to a cryopanel cooled by forced flow liquid helium.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.